Reliability of Operators performing the Visual Inspection of Parenteral Drug Products
dc.contributor.advisor | Morales, José A. | |
dc.contributor.author | Adams Monell, Glorynette | |
dc.date.accessioned | 2020-12-15T13:39:11Z | |
dc.date.available | 2020-12-15T13:39:11Z | |
dc.date.issued | 2010 | |
dc.description | Design Project Article for the Graduate Programs at Polytecnic University of Puerto Rico | en_US |
dc.description.abstract | The visual inspection of parenteral product filled vials is performed to assure that any damaged or defective unit is detected and removed prior to packaging. This investigation evaluated the visual inspection process of parenteral products with manual handling to enhance actual process and reduce regulatory exposure. It challenged the probabilistic inspection results due to variability within operators and inspection time. A total of three (3) different standard sets of 100 vials each were evaluated by three (3) inspectors of high, medium and low experience level. The study concluded with a 95% confidence level that there is no significant difference between the results obtained at forty (40) and fifty (50) seconds inspection time neither between the interaction of inspectors and inspection time but that there is significant difference between operators. Consequently, initial and continuous training are essential elements for the quality assurance of the visual inspection process. Key Terms – analysis of variance, operators reliability, parenteral products, visual inspection | en_US |
dc.identifier.citation | Adams Monell, G. (2010). Reliability of operators performing the visual inspection of parenteral drug products [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/988 | |
dc.language.iso | en_US | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.haspart | San Juan | en_US |
dc.relation.ispartof | Manufacturing Engineering; | |
dc.relation.ispartofseries | Spring-2010; | |
dc.rights.holder | Polytechnic Universy of Puerto Rico, Graduate School | en_US |
dc.rights.license | All rights reserved | en_US |
dc.subject.lcsh | Analysis of variance | en_US |
dc.subject.lcsh | Pharmaceutical technology--Quality control | |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | |
dc.title | Reliability of Operators performing the Visual Inspection of Parenteral Drug Products | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
- Name:
- Articulo Final_ Glorynette Adams.pdf
- Size:
- 472.93 KB
- Format:
- Adobe Portable Document Format
- Description:
- Articulo Final_ Glorynette Adams
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.63 KB
- Format:
- Item-specific license agreed upon to submission
- Description: