Filling Line Improvements to avoid the Defect of Product on the Stopper for Sterile Syringes
| dc.contributor.advisor | Morales Morales, José A. | |
| dc.contributor.author | Rivas Rodríguez, Emeris | |
| dc.date.accessioned | 2022-12-20T13:00:00Z | |
| dc.date.available | 2022-12-20T13:00:00Z | |
| dc.date.issued | 2022 | |
| dc.description | Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico | en_US |
| dc.description.abstract | This research aims to optimize the syringes filling line at the facility to not exceed the action limits because of the defect of syringes with product on the stopper. The product or liquid on the stopper of the syringe is one of the defects that can be encountered in sterile solutions for subcutaneous administration. This defect is classified as major, and the established control limit is not more than (NMT) 1.0%. The project implementation will reduce the defect of syringes with product on the stopper to ensure the manufacturing of the product according to the quality standards and lowest customer risk. Futhermore, will reduce re-inspection lots, the product cost, and Quality Events. Key Terms -- Product on the stopper, Sterile solutions, Sterile solutions filling line, syringe defect. | en_US |
| dc.identifier.citation | Rivas Rodríguez, E. & Morales Morales, J. A. (2022). Filling Line Improvements to avoid the Defect of Product on the Stopper for Sterile Syringes [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico. | en_US |
| dc.identifier.uri | http://hdl.handle.net/20.500.12475/1776 | |
| dc.language.iso | en | en_US |
| dc.publisher | Polytechnic University of Puerto Rico | en_US |
| dc.relation.haspart | San Juan | en_US |
| dc.relation.ispartof | Manufacturing Competitiveness; | |
| dc.relation.ispartofseries | Fall-2022; | |
| dc.rights.holder | Polytechnic University of Puerto Rico, Graduate School | en_US |
| dc.rights.license | All rights reserved | en_US |
| dc.subject.lcsh | Syringes | en_US |
| dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | en_US |
| dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Posters | en_US |
| dc.subject.lcsh | Manufactures--Defects | |
| dc.title | Filling Line Improvements to avoid the Defect of Product on the Stopper for Sterile Syringes | en_US |
| dc.type | Article | en_US |
Files
Original bundle
1 - 2 of 2
Loading...
- Name:
- PUPR_CEAH_SJU_FA22_MMC_Emeris Rivas Rodríguez_Article.pdf
- Size:
- 556.95 KB
- Format:
- Adobe Portable Document Format
- Description:
- PUPR_CEAH_SJU_FA22_MMC_Emeris Rivas Rodríguez_Article
Loading...
- Name:
- PUPR_CEAH_SJU_FA22_MMC_Emeris Rivas Rodríguez_Poster.pdf
- Size:
- 341.4 KB
- Format:
- Adobe Portable Document Format
- Description:
- PUPR_CEAH_SJU_FA22_MMC_Emeris Rivas Rodríguez_Poster
License bundle
1 - 1 of 1
- Name:
- license.txt
- Size:
- 1.63 KB
- Format:
- Item-specific license agreed upon to submission
- Description: