Monomer’s Residuals Test Elimination for Soft Acrylic Buttons at Polytechnic University of Puerto Rico
dc.contributor.advisor | Morales, José A. | |
dc.contributor.author | Vargas Lugo, Bethzaily | |
dc.date.accessioned | 2022-07-06T17:57:07Z | |
dc.date.available | 2022-07-06T17:57:07Z | |
dc.date.issued | 2022 | |
dc.description | Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico | en_US |
dc.description.abstract | In the cataract surgery, the natural lens in the eye is replace with an Intraocular Lens. Five monomers (EA/EMA, TFEMA, EGDMA, UV Chr) are mixed to produce the soft acrylic lens. Residual monomer testing measures the amount of monomer and crosslinker not polymerized or removed by annealing process. During the last years residual monomer testing become a high-cost test due to equipment maintenance, chemical purchases, and spare parts cost. Historical data was collected from the residual testing for Optiblue from January 2019 up to May 2020and Opal from June 2018 up to May 2020. DMAIC methodology was used in this analysis. Process Performance Index (Ppk) value varies from 5.62 to 49.52 for Opal and 2.09 to 30.00 for Optiblue, which confirm annealing process is a capable and is in statistically control. Trend analysis was performed, and no negative trend was observed. Therefore, the monomer residual test can be eliminated. KeyTerms⎯ Residual Monomer Testing, Opal, Optiblue, Process Performance Index. | en_US |
dc.identifier.citation | Vargas Lugo, B. (2022). Monomer’s Residuals Test Elimination for Soft Acrylic Buttons at Polytechnic University of Puerto Rico [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12475/1627 | |
dc.language.iso | en | en_US |
dc.publisher | Polytechnic University of Puerto Rico | en_US |
dc.relation.haspart | San Juan | en_US |
dc.relation.ispartof | Manufacturing Competitiveness; | |
dc.relation.ispartofseries | Spring-2022; | |
dc.rights.holder | Polytechnic University of Puerto Rico, Graduate School | en_US |
dc.rights.license | All rights reserved | en_US |
dc.subject.lcsh | Six sigma (Quality control standard) | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Research | en_US |
dc.subject.lcsh | Polytechnic University of Puerto Rico--Graduate students--Posters | en_US |
dc.subject.lcsh | Monomers | |
dc.subject.lcsh | Intraocular lens industry | |
dc.title | Monomer’s Residuals Test Elimination for Soft Acrylic Buttons at Polytechnic University of Puerto Rico | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 2 of 2
Loading...
- Name:
- PUPR_CEAH_SJU_SP22_MMC_Bethzaily Vargas Lugo_Article.pdf
- Size:
- 620.12 KB
- Format:
- Adobe Portable Document Format
- Description:
- PUPR_CEAH_SJU_SP22_MMC_Bethzaily Vargas Lugo_Article
Loading...
- Name:
- PUPR_CEAH_SJU_SP22_MMC_Bethzaily Vargas Lugo_Poster.pdf
- Size:
- 446.55 KB
- Format:
- Adobe Portable Document Format
- Description:
- PUPR_CEAH_SJU_SP22_MMC_Bethzaily Vargas Lugo_Article
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.63 KB
- Format:
- Item-specific license agreed upon to submission
- Description: