Design of a Double Pipe Heat Exchanger in Counter Flow Configuration Using Numerical Analysis
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Polytechnic University of Puerto Rico
Abstract
The Double Pipe Heat Exchanger in counter flow configuration consists of one fluids flow from the inner pipe while the other flows in the opposite direction from the outer pipe. This project analyzed and designed this heat exchanger utilizing numerical simulation in ANSYS and facilitated optimization by performing a change in the inner tube material. Based on the second simulation analysis the minimum percentage difference was reduced from 2.70% to 0.70%. When changing the inner tube material to copper and maintaining the same initials conditions a 12.07 K decrease in temperature difference was achieved for the hot water. It is found that the visualization of the distribution of the temperature and pressure that numerical simulation provides, gives a better understanding of the heat exchanger and having the system model in ANSYS useful for optimization. Key Terms⎯ ANSYS, Heat Transfer, Optimization and Simulation.
Description
Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico
Keywords
Citation
Pérez Capó, K. & Restrepo Torres, B. (2022). Design of a Double Pipe Heat Exchanger in Counter Flow Configuration Using Numerical Analysis [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico.