Research in the Requirements for Reducing the Blood Transfer Device Complains for Air Bubbles and Leakage

dc.contributor.advisorTorres, Edgar
dc.contributor.authorLorenzo Vargas, Otilio
dc.date.accessioned2020-07-15T18:00:49Z
dc.date.available2020-07-15T18:00:49Z
dc.date.issued2017
dc.descriptionDesign Project Article for the Graduate Programs at Polytechnic University of Puerto Ricoen_US
dc.description.abstractAn increase on complain trigger a company Quality department raising a flag for further investigation of a product Nonconformance. Using Lean Six Sigma tools and DMAIC methodology a multidisciplinary team work together to found possible root cause that create robust process and brings back customer confident. Following the Existing Process Failure mode analysis and customer experiences, a route to follow was created to pursue some corrective action activities that address the failure study. Design of experiment and process validation prove that there was some process opportunities that’s needs to be implemented. Also during the Analyze phase some recommendation were found to pursue as a long term solution. Key Terms - CAPA, Complains, DMAIC, Lean Principals.en_US
dc.identifier.citationLorenzo Vargas, O. (2017). Research in the requirements for reducing the blood transfer device complains for air bubbles and leakage [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico.en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12475/400
dc.language.isoen_USen_US
dc.publisherPolytechnic University of Puerto Ricoen_US
dc.relation.haspartSan Juanen_US
dc.relation.ispartofManufacturing Engineering;
dc.relation.ispartofseriesFall-2017;
dc.rights.holderPolytechnic University of Puerto Rico, Graduate Schoolen_US
dc.rights.licenseAll rights reserveden_US
dc.subject.lcshSix sigma (Quality control standard)
dc.subject.lcshLean manufacturing
dc.subject.lcshBlood--Filtration
dc.subject.lcshPolytechnic University of Puerto Rico--Graduate students--Research
dc.titleResearch in the Requirements for Reducing the Blood Transfer Device Complains for Air Bubbles and Leakageen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Articulo Final_Otilio Lorenzo.pdf
Size:
522.69 KB
Format:
Adobe Portable Document Format
Description:
Articulo Final_Otilio Lorenzo

License bundle

Now showing 1 - 1 of 1
License Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: