Optimization of Filters Changes in Dust Collector CPO-1005 for Coating Machine Number 1
Date
Authors
Advisor
Publisher
Polytechnic University of Puerto Rico
Item Type
Article
- Total Views Total Views4
- Total Downloads Total Downloads2
Abstract
The pharmaceutical industry has dust collectors to remove particulate generated by the coating machines.Actually a pharmaceutical presents a problem in one of the Accela-Cotamachines because obstruction on filters in the dust collector and they have to turn off the coating machine many times in a batch. The company needs to optimize the functionality of the coating machine to improve the production. This project is focus in the optimization in filters changes in dust collector CPO-1005 and wants to reduce the frequency from every 3 months to every 12 months. The importance for the changes of these filters is because the vacuum in the coating machine. If there not vacuum in the Accela-Cota, the machine sends an alarm and turn off the system because had an increase in pressure. KeyTerms: Accela-Cota,Dust Collector, Coating Machine, Vacuum.
Description
Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico
Keywords
Citation
Rivera, E. (2012). Optimization of filters changes in dust collector CPO-1005 for coating machine number 1[Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico.