Optimization of Zero Count Parameter Settings to Improve Equipment Reliability and Reduce Maintenance Costs

dc.contributor.advisorNieves Castro, Rafael A.
dc.contributor.authorCruz Nieves, Gabriela
dc.date.accessioned2026-03-18T15:18:11Z
dc.date.issued2025
dc.descriptionDesign Project Article for the Graduate Programs at Polytechnic University of Puerto Rico
dc.description.abstractThe purpose of this research was to optimize the zero-count verification methodology used in non-viable particle counting equipment for pharmaceutical environmental monitoring. The existing practice required a single-sample zero count with an absolute zero acceptance criterion performed before every sampling point, leading to excessive failures, unnecessary equipment downtime, and increased maintenance costs without improving performance. Historical zero count failure data and maintenance records were analyzed to assess the impact of this approach. Manufacturer calibration guidelines, which define zero count verification as a 10-sample run with acceptance based on the last six samples meeting zero count criteria, served as the technical basis for revising both acceptance criteria and testing frequency. The revised methodology implemented one zero count per sampling session, with additional tests conducted only under predefined trigger conditions. Results showed a substantial reduction in failures, improved equipment availability, and decreased maintenance interventions, demonstrating greater reliability and operational efficiency. Keywords ⎯ Environmental monitoring, manufacturer calibration guidelines, particle counting equipment, zero count verification.
dc.identifier.citationCruz Nieves, G. (2025). Optimization of Zero Count Parameter Settings to Improve Equipment Reliability and Reduce Maintenance Costs [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico.
dc.identifier.urihttps://hdl.handle.net/20.500.12475/3277
dc.language.isoen
dc.publisherPolytechnic University of Puerto Rico
dc.relation.haspartSan Juan
dc.relation.ispartofManufacturing Competitiveness Program
dc.relation.ispartofseriesWinter-2025
dc.rights.holderPolytechnic University of Puerto Rico, Graduate School
dc.rights.licenseAll rights reserved
dc.subject.lcshPolytechnic University of Puerto Rico--Graduate students--Research
dc.subject.lcshPolytechnic University of Puerto Rico--Graduate students--Posters
dc.subject.lcshPolytechnic University of Puerto Rico--Subject headings--Unassigned
dc.titleOptimization of Zero Count Parameter Settings to Improve Equipment Reliability and Reduce Maintenance Costs
dc.typeArticle
dc.typePoster

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
PUPR_CEAH_SJU_WI25_MMC_Gabriela Cruz_Article.pdf
Size:
356.69 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
PUPR_CEAH_SJU_WI25_MMC_Gabriela Cruz_Poster.pdf
Size:
613.53 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
License Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: