Simplification of the Weighing Process in the Raw Material Dispensing Unit
Date
Authors
Advisor
Publisher
Polytechnic University of Puerto Rico
Item Type
Article
- Total Views Total Views2
- Total Downloads Total Downloads7
Abstract
The weighing of excipients on the Rapid Material Unit for buffer formulation takes too long to be completed. The leading causes of this problem are the need for more standardization throughout the process, the inefficient distribution of excipients, and the lack of training for manufacturing personnel. The weighing process was studied to reduce the time it takes to complete a weight
campaign. It was found that by creating a new design structure for the fragmentation and adding the instructions to the operational documents, 3.15 hours were reduced, enabling the process to become more agile, therefore increasing its productivity. Key Terms ⎯ aseptic processing, simplification, pharmaceutical, weighing.
Description
Design Project Article for the Graduate Programs at Polytechnic University of Puerto Rico
Keywords
Citation
Rios Bosques, K. (2023). Simplification of the Weighing Process in the Raw Material Dispensing Unit [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico.