Coating Suspension Holding Time Validation for X’s Tablets in 300L Tanks

dc.contributor.advisorNieves Castro, Rafael A.
dc.contributor.authorPagán Ramos, Natalie E.
dc.date.accessioned2025-07-23T17:02:47Z
dc.date.issued2025-05
dc.descriptionDesign Project Article for the Graduate Programs at Polytechnic University of Puerto Rico
dc.description.abstractThe validation of the 72-hour holding time for coating suspensions used in the production of X's tablets is crucial for improving manufacturing efficiency and reducing costs. X's tablets, which treat type 2 diabetes and obesity, are produced in six different strengths using a continuous, direct compression platform followed by an aqueous non-functional color coating process. The current 24-hour holding time leads to material waste and production interruptions. Extending the holding time to 72 hours ensures the microbial stability of the suspensions. The validation process involves preparing three suspensions in 300L tanks and assessing microbial growth at various intervals. The study confirms that the suspensions meet microbial growth acceptance criteria over the extended period, supporting sustainable large-scale production while maintaining high-quality standards. Key Terms - Coating, Hold Time, Suspension, and Titanium Dioxide.
dc.identifier.citationPagán Ramos, N. E. (2025). Coating Suspension Holding Time Validation for X’s Tablets in 300L Tanks [Unpublished manuscript]. Graduate School, Polytechnic University of Puerto Rico.
dc.identifier.urihttps://hdl.handle.net/20.500.12475/3094
dc.language.isoen
dc.publisherPolytechnic University of Puerto Rico
dc.relation.haspartSan Juan
dc.relation.ispartofManufacturing Competitiveness Program
dc.relation.ispartofseriesSpring-2025
dc.rights.holderPolytechnic University of Puerto Rico, Graduate School
dc.rights.licenseAll rights reserved
dc.subject.lcshPolytechnic University of Puerto Rico--Graduate students--Research
dc.subject.lcshPolytechnic University of Puerto Rico--Graduate students--Posters
dc.subject.lcshPolytechnic University of Puerto Rico--Subject headings--Unassigned
dc.titleCoating Suspension Holding Time Validation for X’s Tablets in 300L Tanks
dc.typeArticle
dc.typePoster

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
PUPR_CEAH_SJU_SP25_MMC_Natalie Pagan_Article.pdf
Size:
443.61 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
PUPR_CEAH_SJU_SP25_MMC_Natalie Pagan_Poster.pdf
Size:
586.08 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
License Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: