Diseño computadorizado de la carga térmica para el acondicionamiento de aire en Puerto Rico (AIRPAK 123 TM)
| dc.contributor.author | Tirado, Alberto | |
| dc.contributor.author | López, Félix | |
| dc.date.accessioned | 2022-04-18T14:09:19Z | |
| dc.date.available | 2022-04-18T14:09:19Z | |
| dc.date.issued | 1993-12 | |
| dc.description | Volumen 3, Número 2, Diciembre 1993 | en_US |
| dc.description.abstract | A digital program to compute the industrial air conditioned load was designed. It took us over 3,000 hours to obtain a reliable product which excels all air conditioned programming standards known to this moment. The program was given the name AIRPAK 123 TM and was judged an excellent product by the group of people present when it was shown for the first time. In this article we present all the equations that make up the subroutines of AIRPAK 123TM. This program is optimized for Puerto Rico, with tables and values calculated for the latitude 18.5. | en_US |
| dc.identifier.citation | Tirado, A. & López, F. (1993). Diseño computadorizado de la carga térmica para el acondicionamiento de aire en Puerto Rico (AIRPAK 123 TM), Revista de la Universidad Politécnica de Puerto Rico, 3(2), 119-145. | en_US |
| dc.identifier.uri | http://hdl.handle.net/20.500.12475/1464 | |
| dc.language.iso | es | en_US |
| dc.publisher | Polytechnic University of Puerto Rico | en_US |
| dc.relation.haspart | San Juan | en_US |
| dc.relation.ispartof | Revista de la Universidad Politécnica de Puerto Rico; | |
| dc.rights.holder | Esta Junta Editorial y la Universidad Politécnica de Puerto Rico hacen constar y reconoce que los autores de los artículos, obras literarias y artísticas publicadas en esta Revista Politechnê, se reservan enteramente los derechos de autor y de publicación de los mismos para los efectos de cualquier ventualidad literaria, publicitaria o de cualquier índole. | en_US |
| dc.rights.license | All rights reserved | en_US |
| dc.subject.lcsh | Airpak 123 (Computer program) | en_US |
| dc.subject.lcsh | Polytechnic University of Puerto Rico--Undergraduates--Research | en_US |
| dc.subject.lcsh | Variable air volume systems (Air conditioning) | |
| dc.title | Diseño computadorizado de la carga térmica para el acondicionamiento de aire en Puerto Rico (AIRPAK 123 TM) | en_US |
| dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- PUPR_SJU_CEAH_Publicaciones_Revista UPPR_Vol03_Num02_Diciembre 1993_P119_Félix López_Alberto Tirado_Article.pdf
- Size:
- 797.19 KB
- Format:
- Adobe Portable Document Format
- Description:
- PUPR_SJU_CEAH_Publicaciones_Revista UPPR_Vol03_Num02_Diciembre 1993_P119_Félix López_Alberto Tirado_Article
License bundle
1 - 1 of 1
- Name:
- license.txt
- Size:
- 1.63 KB
- Format:
- Item-specific license agreed upon to submission
- Description: